Skip to main content

Scam alert: we never charge candidates.

Cardiovascular & Vascular · Recruiting

Cardiac Rhythm Management (CRM) Recruiting.

Cardiac rhythm management covers implantable cardiac devices, pacemakers and implantable cardioverter-defibrillators (ICDs), within our Medical Device recruiting work.

Try Free

Life Sciences Role X-Ray · Free

Have an open cardiac rhythm management (CRM) role?

Free in seconds, no email needed. Add your work email for the full read.

The Cardiac Rhythm Management (CRM) Recruiting Market

CRM is a tightly held category dominated by a small number of established device manufacturers. It covers ICDs, CRT-Ds, pacemakers, leads, leadless pacing, and the remote-monitoring stack on top of them. Field roles spend their days in EP labs and cardiology offices supporting implant procedures and follow-up programming. Hiring well means finding reps who have built relationships with the implanting electrophysiologists in their territory. Beyond the commercial team, CRM programs need regulatory and quality candidates with direct experience in implantable-device design controls, since a pacemaker or ICD carries a different reliability bar than most other device categories.

Cardiac Rhythm Management Recruiting Considerations

In searches such as Regional Sales Director, field sales, and senior product management, candidates typically need genuine comfort in the cath lab or EP lab. This is implant-procedure-adjacent selling with long-term, relationship-driven account management, not a transactional sales model.

Where the candidates are

Implantable cardiac device manufacturers.

Recent Cardiac Rhythm Management (CRM) placements

Cardiac Rhythm Management (CRM) Recruiting

Roles we recruit in cardiac rhythm management

CRM territories are won by the rep the implanting electrophysiologist already trusts, so look for someone who has spent years in the EP labs and cardiology offices your team is trying to open.

We recruit territory managers and clinical specialists who cover ICD, CRT-D, and pacemaker implants and then own the follow-up programming and device clinic relationship that keeps the account.

We also place product managers across leads, leadless pacing, and conduction system pacing, remote monitoring marketers, and the field service engineers who keep programmers and the monitoring stack running.

This is a narrow category with a small number of established manufacturers, so candidates who have not carried a CRM bag often struggle to break in. Tell us the accounts you want covered, and we map who is already in them.

Territory Manager, CRM
Sales Director, CRM
Clinical Specialist, ICD/Pacemaker
Field Service Engineer
CRM Regional Sales Director
Product Manager, CRM
Sr. Marketing Manager, Remote Monitoring
Clinical Education Manager, CRM
Director, Regulatory Affairs, Implantable Devices
Director, Quality Assurance, CRM
Senior Director, Biologics/Devices Manufacturing, CRM
Director, Product Development Engineering, Implantable Cardiac Devices
Specialties we recruit in Cardiac Rhythm Management (CRM)
The nuances

What makes Cardiac Rhythm Management (CRM) hiring different.

In cardiac rhythm management the implant rate has been falling while the lab around it grows. Across Medicare beneficiaries, cardiac implantable electronic device procedure rates dropped from roughly 494 to 415 per 100,000 between 2013 and 2019 (about a 16% decline), while catheter-based electrophysiology procedures (EP studies and ablations) rose roughly 108% and overtook device implants. For a commercial hire, the job is capturing share, replacements, upgrades and conversions between competing technologies, and a candidate whose numbers came from an expanding market often cannot reproduce them here. The call point is contracting at the same time. A 2025 analysis counted about 2,275 practicing US electrophysiologists, 31% of them aged 61 or older, with roughly 50 more leaving each year than entering. The technical lane is tight for a different reason. CRM platforms are Class III products that stay on one premarket approval and change through supplements, so the experienced engineering, regulatory and quality people carry a decade of institutional memory inside one long-lived platform, and there are very few places to have acquired it.

Commercial hiring

Sales, marketing, market access, medical affairs

Sales, field clinical, marketing, market access and medical affairs. Unlike commercial roles elsewhere in cardiology, a CRM commercial role is largely a service role. It covers implant support in the lab, then clinic days, programming, on-call coverage and remote-transmission follow-up, for a customer base that includes allied professionals as much as physicians. Coverage mechanics are part of the sale. Primary-prevention ICD demand is gated by a documented shared decision-making encounter and by post-MI and post-revascularization waiting periods, and leadless pacing is reimbursed only through coverage with evidence development in CMS-approved studies. A commercial candidate who cannot speak to any of that knows only part of the job.

Technical and clinical hiring

R&D, engineering, clinical, regulatory, quality

R&D, engineering, clinical, regulatory, quality and manufacturing. The technical work here is among the most institutionally deep in cardiovascular device, and its constraints are unlike the rest of cardiology. They are power and current-drain budgets that must hold for a decade inside the body, hermetic packaging verified at helium leak rates, lead mechanics and long-term reliability, and sensing and detection algorithms. Connected implants fall inside the FDA's cyber device definition, so the work also includes a software bill of materials and postmarket vulnerability management under section 524B. Regulatory work is supplement management on an existing PMA (180-day, real-time and panel-track). Post-approval obligations are a staffing line. PMA post-approval studies, section 522 postmarket surveillance orders and CMS coverage-with-evidence-development registries all need people.

What we look for in candidates
  • Whether their number came from category growth, share capture, replacement and upgrade capture, or conversion between technologies, since in a flat implant market those are very different achievements
  • Device-clinic fluency: whether they can describe allied-professional workflow, alert triage and follow-up scheduling, and whether they understand the industry-independence boundary in remote monitoring
  • For field clinical roles, IBHRE Certified Cardiac Device Specialist status or eligibility for it, and where their formal cardiac device training came from
  • Comfort with coverage mechanics as part of the sale, such as shared decision-making documentation for primary-prevention ICDs and evidence-development enrollment for leadless pacing
  • For the newer sub-segments, whether they can proctor and teach an implant technique at the table
  • Technical lane: whether their regulatory or quality experience is PMA supplement work on a long-lived implantable platform, and whether it includes section 522 surveillance or post-approval study obligations
  • Technical lane: which constraint they have actually designed against, since power and longevity, hermetic packaging, lead mechanics, detection algorithms, and connectivity and cybersecurity are separate careers
When to bring us in
  • You are filling a field clinical or clinical specialist role and need IBHRE-certified or certification-eligible candidates, a group defined by the credential
  • You are launching leadless pacing, conduction system pacing or an extravascular system and need people who can proctor and teach at the table
  • Your plan assumes category growth in a segment where implant volumes have been flat to declining, and you want the people who actually qualify and a realistic timeline mapped before you commit to the number
  • You need a regulatory or quality lead with PMA supplement history on a long-lived implantable platform, which is a national search across a very small set of employers
  • You are building a remote-monitoring or connected-device team and are competing for health-IT, platform and product-security engineers
  • The search is confidential because the incumbent is still covering the labs and the device clinic
Sub-markets we cover

How each Cardiac Rhythm Management (CRM) sub-market hires.

ICD / CRT-D

ICD and CRT-D demand is gated by a documented administrative workflow before clinical preference comes into it. Medicare's ICD coverage policy requires a formal shared decision-making encounter using an evidence-based decision tool before an initial primary-prevention implant, and defers implant roughly 40 days after myocardial infarction and 90 days after revascularization. The funnel runs through heart-failure clinics, referral tracking and documentation as much as through the EP lab, and a candidate who has only carried a procedural bag is often surprised by how much of the job is pathway work. CRT-D adds an echo and heart-failure overlay and a second set of physician relationships.

Technical and clinical

High-voltage engineering, a different discipline from pacing. The work is capacitor and charge-time design, defibrillation efficacy testing and, often hardest, detection and discrimination algorithms that separate ventricular arrhythmia from supraventricular rhythm well enough to avoid inappropriate shocks. Clinical roles need arrhythmia event adjudication and multi-year follow-up experience. Acute procedural readouts are a different skill.

Pacemakers

The mature end of the category, and the part where site of service is changing who the customer is. In bradycardia pacing, growth comes from substitution. Pacemaker insertion is payable in the ambulatory surgical center setting under Medicare, which puts a non-hospital economic buyer alongside the hospital service line and value-analysis committee. Territory design and account planning here look less like a hospital-only device business than most of cardiology, and candidates whose entire experience is hospital contracting need that difference made explicit before they are hired.

Technical and clinical

The engineering here is built around longevity. Current-drain budgeting, lithium chemistry selection and automatic capture algorithms all exist to add years to a generator's service life, because every year added removes a replacement procedure. MR-conditional labeling is engineering work with a direct commercial consequence. Medicare covers MRI for a patient with an implanted system according to FDA labeling, and covers systems without that labeling only under restrictive conditions, including 1.5T normal operating mode, no fractured, epicardial or abandoned leads, and a facility checklist.

Leadless Pacing

The only CRM sub-segment where the commercial job includes running a federal evidence-development workflow. Medicare's leadless pacemaker policy makes these devices non-covered outside CMS-approved studies, with claims carrying a research diagnosis code, an investigational-service modifier and a matching trial identifier. The field role carries enrollment and data-submission responsibility alongside case support, and the marketing role is partly an evidence and registry role. The approval of a dual-chamber leadless system in July 2023 raised the training burden again (two implanted devices that communicate with each other, placed in one procedure). Proctoring capacity is usually what limits how fast an account's volume grows.

Technical and clinical

Miniaturization works against longevity here. A leadless device has to deliver the same decade of service life from a fraction of the volume, add docking, repositioning and retrieval mechanics, and run beat-to-beat device-to-device wireless communication inside a power budget that leaves almost no headroom. The engineers here are systems and low-power electronics people, and they overlap only partly with conventional pulse-generator engineers.

Leads & Headers

Much of CRM's long-term risk sits in the leads, and they are often under-staffed until something goes wrong. Leads accumulate over a patient's life, get abandoned, fail and become infection vectors. The extraction call point is a different and much smaller set of centers than the implanting community. The 2026 multi-society expert consensus update on CIED lead management and extraction, published in April 2026, addresses institutional readiness, multidisciplinary extraction teams, operator competency, prevention and treatment of CIED infection, and lead management in the setting of transcatheter tricuspid valve replacement. The buying conversation here is about the extraction program.

Technical and clinical

Reliability and postmarket engineering more than new design: conductor and insulation fatigue, connector and header sealing, and the field-action decision-making that follows, where a corrective action can mean weighing explant of hardware attached to the heart. Section 522 postmarket surveillance orders and PMA post-approval studies concentrate here, so surveillance, biostatistics and complaint-handling people are as scarce as design engineers.

Remote Monitoring

A CRM sub-market that is easy to mis-hire. It is a software, service and clinic-economics business inside a device company. The customer is the device clinic and its staffing math. The 2023 multi-society consensus on remote device clinic management recommends roughly 3.0 full-time equivalents per 1,000 remotely monitored patients, notes that most alerts are clinically non-actionable, and expects a response to red alerts within one business day. Reimbursement runs through the CPT 93294-93298 family, and clinic economics depend on the technical component. The same consensus states that the remote service should be independent of industry and that industry should not participate directly in clinical care, so a manufacturer's hire sells into and supports a workflow the consensus says they should not run. A candidate who cannot explain that boundary is a compliance risk as well as a weak fit.

Technical and clinical

Cloud platform, multi-vendor interoperability, alert triage logic and the connected-device security stack. Vendor-neutral third-party platforms and outsourced monitoring services now compete for the same clinic budget, so the candidates include health-IT and services people as well as device people. The security obligations under section 524B, including a software bill of materials and a postmarket vulnerability plan, mean product security engineers are hired here, on the platform side.

Subcutaneous ICD

A displacement sale inside accounts that already implant transvenous systems, so the commercial job is conversion and the argument is trial evidence. The randomized comparison of subcutaneous and transvenous ICD therapy showed non-inferiority on the composite of device-related complications and inappropriate shocks at roughly 49 months, and its extended follow-up study is examining device-related complications out to eight years. A candidate has to hold a data-level conversation with an implanter who has a settled habit and a good reason for it. Extravascular systems are the newer version of the same argument, adding anti-tachycardia and asystole pacing that a subcutaneous system does not provide. The extravascular pivotal study also reported P-wave oversensing in roughly one in ten patients, requiring lead repositioning. An experienced implanter will raise that objection, so test a candidate on it.

Technical and clinical

Defibrillation without a transvenous coil: shock vector and energy engineering, sensing vector selection and oversensing rejection, and, for extravascular systems, substernal access tooling and lead placement instrumentation. Sensing is the hard problem, and it is signal-processing work more than mechanical work.

His Bundle / Conduction System Pacing

The clearest case in CRM of clinical adoption running ahead of its own infrastructure, so selling it means teaching it. The 2023 cardiac physiologic pacing guideline gave conduction system pacing formal standing, but there are still no CSP-specific CPT codes. Procedures are billed with existing transvenous pacemaker codes by anatomic placement, and dedicated ICD-10-PCS codes for leads placed in the ventricular septum only took effect on April 1, 2026. The technique itself has to be learned at the table, so companies competing here hire people who can proctor an implant and read a septal electrogram. That requirement considerably narrows who qualifies.

Technical and clinical

Lumenless lead and delivery-sheath design with controlled septal fixation depth, plus the programmer-side work of capturing and interpreting pacing electrograms well enough to confirm conduction system capture. It sits between lead mechanics and mapping software. Engineering hires here often come from those two different backgrounds and have to be integrated deliberately.

Where this community gathers

Many of the candidates we place belong to these societies and attend their annual meetings.

Testimonials

What hiring leaders say

I had the pleasure of working with Jacobs Management Group to identify and hire a Director of Regulatory Affairs for our team. They asked thoughtful, clarifying questions and really listened to our specific needs. They presented several highly qualified candidates and guided us patiently through the entire process. Our entire hiring team is thrilled with both the process and the outcome. I highly recommend Jacobs Management Group to anyone looking for a trusted search partner.
Senior Recruiter, Talent AcquisitionMedical Device · Hiring Leader
The Jacobs Management Group team was exceptional at investigating and navigating challenges with the search. Thoughtful, positive, and plan-full in filling our varying requirements in a dynamic organization. True professionals who listen for understanding before making recommendations.
VP, Human ResourcesBiotechnology · Hiring Leader
I've worked with many executive recruiters over the years in the medical device/life sciences industry. I can confidently say that Jacobs Management Group is at the top of the list. They are the consummate professionals and business partners who consistently go above and beyond to ensure a client's needs are both well understood and fulfilled. They are always willing to share information, network, and provide advice - both on a professional and personal level. Jacobs Management Group has undoubtedly earned my respect and I'm proud to call them a trusted partner and friend.
VP, CommercialMid-Cap Medical Device Organization
Read all client testimonials

Data and guides for Cardiac Rhythm Management (CRM) hiring

Hire talent

Get in touch with a specialized recruiter.

Tell us a bit about the role you're hiring for. A few details help us prepare for the first call.

Frequently asked

What hiring leaders ask about cardiac rhythm management (CRM) searches.

Is cardiac rhythm management a growing hiring market?+

Not in unit terms, and that matters when you set a quota. Across Medicare beneficiaries, cardiac implantable electronic device procedure rates fell from about 494 to 415 per 100,000 between 2013 and 2019 (roughly a 16% decline), while catheter-based electrophysiology procedures (EP studies and ablations) rose about 108% over the same window and overtook device implants. Hiring into CRM is about capturing share, replacements, upgrades and conversion between competing technologies, and a candidate whose track record was built in an expanding market does not automatically transfer. The growing roles often sit in the newer sub-segments and in remote monitoring, outside the core implant business.

What makes a CRM field clinical specialist different from a cardiology sales rep?+

The role is quasi-clinical and credential-gated. Field clinical people interrogate and program implanted devices, support implants in the lab, and work alongside a hospital device clinic. Many hold the IBHRE Certified Cardiac Device Specialist credential. Its allied-professional eligibility route requires either a formal cardiac pacing or electrophysiology training program with roughly six months of didactic work plus six months of field exposure, or a Cardiovascular Credentialing International credential plus twelve months of clinical experience. The role also has a boundary to respect. The 2023 multi-society consensus on remote device clinics states that the remote monitoring service should be independent of industry and that industry should not participate directly in clinical care.

Can an ablation or mapping specialist move into cardiac rhythm management?+

Ablation and CRM share a lab and very little else commercially. Ablation is an episodic procedural business judged on case support and lab throughput. CRM is a lifetime-of-patient business where most of the value accrues after the implant, through the device clinic, remote transmissions, programming and eventually a generator replacement. EP lab access and arrhythmia fluency carry over. They do not bring follow-up service discipline, programming depth, on-call reliability or the allied-professional relationships that hold the account together between procedures.

What should I look for in a CRM regulatory or quality hire?+

Look for supplement history on a long-lived platform. Cardiac rhythm devices are Class III products approved through premarket approval, and most ongoing regulatory work modifies an existing PMA through 180-day, real-time and panel-track supplements, alongside the post-approval studies and section 522 postmarket surveillance orders that follow a marketed implantable. Connected devices add section 524B cybersecurity obligations, including a software bill of materials and a plan to monitor and patch postmarket vulnerabilities. A candidate whose experience is 510(k) clearances has done a different job, however strong they are at it.

Why do leadless pacing and conduction system pacing searches behave differently from a standard pacemaker search?+

Because in both cases the commercial job carries work a mature product does not require. Leadless pacemakers are covered by Medicare only under coverage with evidence development in CMS-approved studies, so field and marketing roles hold enrollment and data-submission responsibility on top of case support. Conduction system pacing has no CPT code of its own. It is billed with existing transvenous pacemaker codes by anatomic placement, and dedicated ICD-10-PCS codes for leads placed in the ventricular septum only took effect in April 2026. The implant technique also has to be taught, so the hire has to be able to proctor at the table. Both facts leave the number of people who qualify well below the number a job posting will reach.

What are the nuances in cardiac rhythm management recruiting in medical device and diagnostics?+

CRM hiring turns on implanter relationships and follow-up programming skill, because the rep is in the EP lab during implants and back in the device clinic for interrogations afterward. The manufacturer set is small and long-tenured, so candidates with CRM experience are competitive and in demand, and a mapped, direct approach is what puts you in front of them.